Connecting the inverters
Ever-Solar (Eversol TL RS485)
Solar-Log
1000/500/200
Installation 77 of 268
4 Connect the other inverters to each other in the same way.
5 Terminate in the last inverter in accordance with the inverter instructions.
6 Close inverters.
4.32 Ever-Solar (Eversol TL RS485)
Overview
Interface not integrated. Retrofit RS485 interface card.
Where to connect: RJ45 socket on the outside of the inverter
4 pin connection only on RS485/422 B connection of the Solar-Log™
Communication address does not have to be allocated.

Note
The order in which the inverters are displayed in the Solar-Log™ after detection
is random. We strongly recommend that you change the order of the inverters
immediately after detection at startup, in the Configuration/Basic/Inverter
dialogue box (Page 162).
The inverters can be identified using the displayed serial number.
Work steps
Switch off the inverters and the SolarLog™; Page 17
Install the RS485 interface in the inverter
Connect inverters to the Solar-Log
Connect the inverters to each other
Installing the RS485 interface
Procedure
Insert the RS485 interface in the bottom of the inverter in accordance with
the interface card installation instructions and screw in.
Connecting inverters to the Solar-Log
The wiring is done using the
ready-made BRJ1 data cable (optional extra; not supplied)
or
your own fabricated cable connection with RJ45 plug and terminal
block connector ( Page 15)