Shrnutí obsahu

Strany 1 - User Manual

MAKING MODERN LIVING POSSIBLESOLAR INVERTERSDanfoss TLX CN Pro+ Web ServerUser ManualThree-phase – 10, 12.5 and 15 kW

Strany 2 - 4. Status

• A pop-up window shows the inverters successfully identified.Click [OK] to confirm that the correct number of inverters has been found.Illustration 2

Strany 3

Illustration 2.4: Step 3 of 7: Time and DateTo change these settings later, refer to Setup, Inverter details, Set Date and Time.Step 4 of 7: Installed

Strany 4

Step 5 of 7: Grid codeSelect the grid code to match the location of the installation. To meet medium-voltage grid re-quirements select a grid code end

Strany 5 - 8. Appendix A - Sitemap

Illustration 2.7: Step 6 of 7: ReplicationStep 7 of 7: Inverter startupThe inverter will start automatically when the installation sequence i

Strany 6

2.2. Operation2.2.1. Web Server StructureThe Web Server overview is structured as follows.Illustration 2.9: Overview1. Plant name: Displays the curren

Strany 7 - Remote Connection

menu selected: [Overview]. On some pages, a horizontal menu is provided for im-proved readability.7. Footer: Options on the footer bar:• L

Strany 8

Item Unit View DescriptionPlantandGroupInverterOverall plant sta-tus- x Red: Plant PR < 50 %, or:Any inverter in the network- in fail safe mode,

Strany 9

A security level grants access to all menu items at the same level as well as all menu items of alower security level.Throughout the manual, a [0], [1

Strany 10 - Setup, Setup Details

Requirements for notification by e-mail or sms:• All inverters are TLX CN Pro+ inverters.• The master is connected to the internet or has a GSM modem

Strany 11 - Setup, Calibration, PV Array

3. View3.1.Overview [0] [Plant, Group, Inverter]The layout of the overview screen on both plant, group and inverter basis is described in Chap-ter 2,

Strany 12 - 2. Getting Started

Contents1. Introduction5Introduction 5Disclaimer 5List of Abbreviations 6System Requirements 62. Getting Started8Access and Initial Setup 8Access via

Strany 13

3.2.2. Group ViewClick on the group name to display the group view. In group view, a list of all inverters in thecurrent group is displayed, detailing

Strany 14 - Accessing the

4. Status4.1. StatusAll values displayed in the Status are read-only. To change the inverter settings, see the Setupsection. For a detailed descripti

Strany 15 - Security Levels

4.3.4.Isolation Resistance[0] [Inverter]The isolation resistance between the earth and PV arrays is displayed in Ohm (Ω). The isolationresistance is m

Strany 16

4.6.Reactive Power[1] [Plant]The setpoint type and setpoint value of reactive power are displayed here, for TLX CN Pro+variants only.It

Strany 17 - 2.5.1. Graphs

4.7.4.RPM of Fans[1] [Inverter]The internal fan speed is displayed in RPM.4.7.5.Power Module Temperatures[0] [Inverter]Internal temperature of the inv

Strany 18 - Setup, Messaging

5. Log5.1. LoggingThis section explains the individual logs of the TripleLynx CN Pro. All individual logs can bedownloaded as .csv fil

Strany 19 - 3.2.1. Plant View

Value Unit DescriptionOff-grid counter[0]Hour Total duration of disconnection from grid.Total derate coun-ter[0]Hour Total duration of power productio

Strany 20 - Operation

• Daily energy production data during the past week.• The weekly energy production data for the past 4 weeks.• The monthly energy production for the p

Strany 21

Note: The change log keeps track of all modifications made to parameters accessed at security lev-el 2. The log includes:• Parameter changed• New sett

Strany 22 - [0] [Inverter]

6. Setup6.1.Calibration[0] [Plant, Inverter]Configuration of individual sensors, PV arrays and environmental settings.6.1.1.Sensors[0] [Plant, Inverte

Strany 23 - [1] [Plant]

Maximum Values[0] [Inverter]21Residual Current Monitor [0] [Inverter]21Grid Management[0] [Inverter]21Reactive Power[1] [Plant]22Inverter[0] [Inverter

Strany 24 - [0] [Plant]

Illustration 6.2: PV ArrayItem Unit DescriptionPV1 array aream2Input 1 - total PV array areaPV1 array power W Input 1 - total rated output of PV panel

Strany 25 - [1] [Inverter]

6.2.Communication[0][Plant, Inverter]The communication menu contains the following sub menus; see descriptions below. Some ofthe menus are only visibl

Strany 26

Item DescriptionConfiguration Options:• Manual• AutomaticThe following settings are obtained automatically if automatic configuration is selected, oth

Strany 27

This menu is visible when the master inverter is equipped with a GSM modem and a valid SIMcard.Illustration 6.6: GPRS Setup for GSM networkingNote: In

Strany 28

Note: A correctly configured SMTP server and internet connection, IP and DNS server, are necessa-ry for receiving e-mail messages from the inverter. T

Strany 29 - 6. Setup

6.2.6.Data Warehouse[0] [Plant] / FTP Server UploadIllustration 6.8: Data WarehouseItemDescriptionUpload time[0]Time of day when the upload takes p

Strany 30

6.2.7.Remote Access[2] [Inverter]As per default it is not possible to change the functional safety settings of the inverter via theWeb Server. To be a

Strany 31 - [0][Plant, Inverter]

The alarm is activated by the occurrence of a predefined inverter event. Refer to the TripleLynxCN Reference Manual for a complete list of which event

Strany 32 - GPRS Setup

Item DescriptionInverter name The name of the inverter. At delivery, this name corresponds to the serialnumber of the inverter. A maximum of 15 charac

Strany 33

6.5.Logging[0] [Inverter]6.5.1.Logging Interval[0] [Inverter]Configure the logging interval of the individual inverter at [Inverter → Setup → Logging]

Strany 34

Remote Access[2] [Inverter]35External Alarm[0] [Inverter] 35External Alarm[0] [Inverter]35Inverter Details[0] [Inverter]36General [0] [Inverter]36Date

Strany 35

[Setup → Grid management]Set up ancillary services such as Power Level Adjustment (PLA) and Reactive Power in this area.6.6.1.General[1] [Plant]Illust

Strany 36 - External Alarm[0] [Inverter]

Set point curve Q(U)Reactive power is defined as a function of the grid voltage, either as a percentage of the nomi-nal plant power or directly in kVA

Strany 37 - Inverter Details

Over-excited energy is always displayed above the horizontal axis, and under-excited energybelow the axis.The curve ends are always horizon

Strany 38

Illustration 6.17: Q(U) Set Point Curves - Reactive PowerNote: A pop -up warning appears when an inconsistent pair of values is entered.6.6.4.Fallback

Strany 39

• DW upload• Performance ratio (PR)• Communication error (Com Error)• Data overwrite• Plant statusEach message type can be enabled or disabled individ

Strany 40 - PF(P) Curve

6.7.2.Yield[0] [Plant]Check the 'Enable' option to activate yield notification.Select yield notification interval: Daily, weekly monthly or

Strany 41 - Q(U) Curve

Note: Read the inverter event checklist in the TripleLynx CN User Manual before calling service. Atable describing the different events and the

Strany 42

6.7.5.Performance Ratio[0] [Plant]The follower inverters in the network will use the value from the irradiation sensor connected tothe master inverter

Strany 43 - Messaging

Illustration 6.25: Data Overwrite6.7.8.Plant Status[0] [Plant]Check 'Enable' to activate a plant status e-mail on a daily, weekly or monthly

Strany 44 - SMTP Setup

Plant name: My plant Report date: 30.07.2010 Report period: Yesterday Plant production: 421422 Wh Plant revenue: 126.30 Euro Equivalent

Strany 45

Plant Details[0] [Plant, Inverter]567. Remote Connection57Remote Connection 578. Appendix A - Sitemap58Plant View 58Group View 61Inverter View 62Conte

Strany 46 - Troubleshooting

Content of E-mail NotificationItem Unit DescriptionPlant name - The name of the plant.Report date dd-mm-yyyy The reporting date.Report period - The re

Strany 47

6.10.Setup Details[0] [Plant, Inverter]6.10.1.Details[0] [Inverter]Enter the language and grid code of the inverter here.Illustration 6.27: Setup Deta

Strany 48

Item DescriptionROCOF limit[2]Trip setting in Hz/sTime to disconnect[2]Time limit for inverter disconnection from grid.6.10.4.PV Configuration[1] [Inv

Strany 49

Illustration 6.30: Power Level AdjustmentItemDescriptionK1-K4 active Enable (check) or disable (uncheck) the individual inputs, K1-K4.If the input is

Strany 50

Note: It is only possible to replicate the settings of the master inverter to the other inverters in thenetwork.6.11.2.Settings Backup[1] [Inverter]Wh

Strany 51

Illustration 6.31: Settings Backup & RestoreItem DescriptionBackup ‘Dumps’ the settings and the content of the production log of the particula

Strany 52 - Power Level Adjustment

Note: In case the username or password is forgotten, the current username and password can bereset via the display. This is done via [Setup → Reset pa

Strany 53 - 6.11. Service[1] [Plant]

Each user is referenced via the name configured in the users menu (see above).All groups belonging to the master inverter are automatically added

Strany 54

7. Remote Connection7.1. Remote ConnectionFor network management purposes, the following inverter ports are used for communication:Application Protoco

Strany 55 - Web Server

8. Appendix A - Sitemap8.1. Plant View[x] Defines current security level, where x is 0, 1 or 2.[*] Defines whether this page is shown when logged in a

Strany 56 - Supported Charac

1. Introduction1.1. IntroductionThese instructions describe the TripleLynx CN Pro Web Server and explain how to use it.Refer to the download area at w

Strany 57 - Supported Characters

Main Menu Horizontal menu Page content[0] Setup ↳Submenu [0] Calibration [0] Sensors [0] Irradiation sensor scale: mV(1000 W/m2)[0] Irradiation s

Strany 58

Main Menu Horizontal menu Page content[0] Setup ↳Submenu [0] Messaging [0] Recipient [0] Recipient ID[0] Recipient Alias[0] Language[0] SMS[0] Em

Strany 59

8.2. Group ViewMain Menu Horizontal menu Page content[0] [*] View ↳Submenu [0] [*] Overview Displays the main page with over-all group status[

Strany 60

8.3. Inverter ViewMain Menu Horizontal menu Page content[0] [*] View ↳Submenu [0] [*] Overview Displays the main page with over-all inverter s

Strany 61

Main Menu Horizontal menu Page content↳Submenu [0] AC grid [0] Present valuesOn Phase 1 (L1): Phase 2 (L2):Phase 3 (L3)[0] Voltage: V[1] 10 min.

Strany 62 - 8.2. Group View

Main Menu Horizontal menu Page content↳Submenu [0] Grid management2 [0] Power level adjustment[0] Power level adjustment: %[0] Current production:

Strany 63 - 8.3. Inverter View

Main Menu Horizontal menu Page content↳ [1] Operating timePower board[1] POW: hAUX board: 2341 h[1] AUX: hControl board: 2341 h[1] CTRL: hCommunicat

Strany 64

Main Menu Horizontal menu Page content[0] Setup ↳Submenu [0] Calibration [0] Sensors [0] Irradiation sensor scale: mV(1000 W/m2 )[0] Irradiation

Strany 65

Main Menu Horizontal menu Page content↳[1] Service [1] Settings backup Performs a settings backup or arestore of the backed up settings.[1] Settings r

Strany 66

Danfoss Solar Inverters A/SUlsnaes 1DK-6300 GraastenDenmarkTel: +45 7488 1300Fax: +45 7488 1301E-mail: [email protected].

Strany 67

Symbol Explanatory noteItalics1) Indicates reference to a section of the present manual.2) Italics are also used to indicate an operation mode,e.g. op

Strany 68

For all language versions, the Web Server software supports characters compatible with Uni-code.For plant, group and inverter name, only

Strany 69 - Danfoss Solar Inverters A/S

2. Getting Started2.1. Access and Initial Setup2.1.1. Access via PC Ethernet InterfaceChange the Web Server logon and password of the master in