Danfoss TripleLynx CN Instalační manuál

Procházejte online nebo si stáhněte Instalační manuál pro Napájecí adaptéry a střídače Danfoss TripleLynx CN. Danfoss TripleLynx CN Installation manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Manual

TripleLynx CNInstallation ManualThree-phase – 10, 12.5 and 15 kWMAKING MODERN LIVING POSSIBLESOLAR INVERTERS

Strany 2 - Contents

Illustration 3.1: Safe DistancesObserve these distances when installing one or more inverters. One row mounting is recom-mended. Contact

Strany 3 - 1. Safety and Conformity

3.2. Mounting the InverterFor safe handling of the inverter, two people must carry the unit, or a suitabletransport trolley must be used

Strany 4 - PV Load Switch

Illustration 3.5: Place Inverter in MountingBracketPlace the lower part of the inverter againstthe mounting bracket.Illustration 3.6: Fast

Strany 5 - 1.4. Conformity

3.3. Removing the InverterLoosen the locking screws on either side of the inverter.Removal is performed in the reverse order of mounting. With a firm

Strany 6 - 2. Introduction

Illustration 3.8: Open the InverterPush the front cover upwards. When a slightresistance is felt, give the front cover a tapon the bottom t

Strany 7 - 2.1.1. Installation Sequence

Illustration 3.10: Fasten Front Screws and En-sure Proper PE ConnectionThe two front screws are the PE connection to the front cover.

Strany 8 - 2.1.2. Overview of Inverter

Illustration 3.11: AC Cable Wire StripLegend1 Blue cable - Neutral2 Yellow/green cable - EarthThe illustration shows the stripping of insulation of al

Strany 9

8. Close the front cover, and remember to verify that both front screws are applied withthe correct torque to obtain PE connection.9. Close main circu

Strany 10 - 3. Installation

When unmated the MC4 connectors are not IP54. The intrusion of moisture mayoccur in the following situations:1. The inverter runs in Master/Slave oper

Strany 11 - 3.2. Mounting the Inverter

4. Start-up and Check of Settings4.1. Start-up and Check of SettingsNote: Due to the advanced functionalities of the inverter, it may take up to 10 se

Strany 12

Contents1. Safety and Conformity2Important Safety Information 2Hazards of PV Systems 3PV Load Switch 3Conformity 42. Introduction5Introduction 5Instal

Strany 13 - 3.3. Removing the Inverter

Illustration 4.2: Set TimeSet time as prompted by the display. Press'OK' to select number. Press ‘ ▲ ’ to scroll upthrough the numb

Strany 14

Illustration 4.4: Installed PV PowerEnter the amount of installed PV power foreach of the PV inputs. When two or more PVinputs are connected in

Strany 15 - 3.5. AC Grid Connection

Note: If the two grid code selections do not match they will be cancelled and it will be necessary toredo the selections. If an incorrect grid cod

Strany 16

Illustration 4.7: Master ModeTo enable Master mode go to the Inverterdetails menu [Setup → Inverter details →Master mode] and set Master

Strany 17 - 3.6. PV Connection

5. Technical Data5.1. Technical DataNomen-cla-ture 1)Parameter TripleLynx CN8 kWTripleLynx CN10 kWTripleLynx CN12.5 kWTripleLynx CN15 kW AC Pa

Strany 18 - Auxiliary Input/Output

1) According to FprEN 50524.2) For fixed systems with semi-optimal conditions.3) At identical input voltages. At unequal input voltages, Vmppmin can b

Strany 19 - 18 L00410580-01_02

5.4. Cable RequirementsCable Condition SpecificationAC 5 wire cable CopperOuter diameter 18-25 mmInsulation strip All 5 wires 16 mmMax. recommended

Strany 20 - Illustration 4.3: Set Date

Illustration 5.2: TripleLynx CN 10 kW Cable Losses [%] versus Cable Length [m]Illustration 5.3: TripleLynx CN 12.5 kW Cable Losses [%] versus Cable Le

Strany 21 - 20 L00410580-01_02

5.5. Torque Specifications for InstallationIllustration 5.5: Overview of Inverter with Torque Indications, 1-3Illustration 5.6: Overview of Inverter w

Strany 22 - Master Mode

5.6. Auxiliary Interface SpecificationsParameter Parameter Details SpecificationSerial Communication RS485Common cable specificationCable jacket dia

Strany 23 - 22 L00410580-01_02

1. Safety and Conformity1.1. Important Safety InformationAll persons installing and servicing inverters must be:• Trained and experienced in general s

Strany 24 - 5. Technical Data

1) Max. number of inverters are 100. If GSM modem is used for portal upload, the amount of inverters in anetwork is limited to 50.2) For outdoor use,

Strany 25 - 5.3. Installation

RS485Terminate the RS485 communication bus at both ends.To terminate the RS485 bus:• Connect Bias L to RX/TX B• Connect Bias H to RX/TX AThe RS485 add

Strany 26 - 5.4. Cable Requirements

5.6.1. Network TopologyThe inverter has two Ethernet RJ45 connectors enabling the connection of several inverters in aline topology as an alternative

Strany 27

Rev. date 2011-11-16 Lit. No. L00410580-01_02Danfoss Solar Inverters A/SUlsnaes 1DK-6300 GraastenDenmarkTel: +45 7488 1300Fax: +45 7488 1301E-mail:

Strany 28

Before installation:Check for damage to inverter and packaging. If in doubt, contact the supplier be-fore installing the inverter.Installation:For opt

Strany 29

1.4. ConformityFor approvals and certification information, go to the download area at• www.danfoss.com/solar, Approvals and Certifications• www.danfo

Strany 30

2. Introduction2.1. IntroductionThis manual explains the installation and setup of the TripleLynx CN solar inverter, for the in-stallation technician.

Strany 31

Product LabelIllustration 2.2: Product LabelThe product label on the side of the invertershows:• Inverter type• Important specifications• Serial numb

Strany 32 - 5.6.1. Network Topology

2.1.2. Overview of InverterIllustration 2.3: Overview of Danfoss TLX CN inverterLive Part1. AC Connection Area2. DC Connection Area3. Terminal block f

Strany 33 - Danfoss Solar Inverters A/S

3. Installation3.1. Installation Dimensions and PatternsNote: When choosing the installation place, ensure that all labels are visible at all times.Fo

Komentáře k této Příručce

Žádné komentáře