Solar-Log1000: Configuration at the unit
Performing the initial configuration (Config./Start/Initial configuration)
Solar-Log
1000/500/200
Installation 211 of 268
10.3.3 Current meter on S0 input
This can be used to activate a current meter if there is one connected to the
S0 input, or exclude it if none is connected.
The current meter is managed by Solar-Log
1000
as a virtual inverter. It is assigned
the number 1, and all other real inverters are numbered starting from there.
1 Touch Yes (= Activate input) or No (= Deactivate input)
2 Touch Save, then Next to go to the next dialogue.
Inverter detection
As the initial configuration is intended to provide a quick way of getting the
system up and running, the Inverter detection dialogue can be opened di-
rectly here ( Seite 212).
Procedure
Touch Go to inverter detection
or
If inverter detection is to be performed at a later time using the Inverter de-
tection menu item, the settings made up to this point can be saved:
Touch Save