82 User Guide DLX Series L00410623-1
Figure 8.2.7: Checking the AC varistors
Table 8.1: Measure if the varistors are damaged
Measurements Undamaged Replace
Between GND (1) and the left VDR (2)
0 Ω ∞ Ω
Between
N
(3) and the middle VDR (4)
0 Ω ∞ Ω
Between GND (3) and the right VDR(5)
0 Ω ∞ Ω
Replacement Procedure
Use the service tool delivered in the packaging with the new varistors ordered from
Danfoss. The service tool is designed as a fork, and can open up all terminal clamps
simultaneously.
Figure 0.1: Service tool to open the varistor terminal clamps
Open the terminal clamps and remove the damaged varistor(s).
Comply with Figure 8.2.5 and 8.2.6 to get the position of the varistors correct.
Also use the service tool to open the clamps when inserting the new varistor(s).