82 User Guide DLX Series L00410623-1
Figure 8.2.7: Checking the AC varistors
Table 8.1: Measure if the varistors are damaged
Measurements Undamaged Replace
Between GND (1) and the left VDR (2)
0 Ω ∞ Ω
Between
(3) and the middle VDR (4)
0 Ω ∞ Ω
Between GND (3) and the right VDR(5)
0 Ω ∞ Ω
Replacement Procedure
• Use the service tool delivered in the packaging with the new varistors ordered from
Danfoss. The service tool is designed as a fork, and can open up all terminal clamps
simultaneously.
Figure 0.1: Service tool to open the varistor terminal clamps
• Open the terminal clamps and remove the damaged varistor(s).
• Comply with Figure 8.2.5 and 8.2.6 to get the position of the varistors correct.
• Also use the service tool to open the clamps when inserting the new varistor(s).