User Guide DLX Series L00410623-1 71
6.4.3. Setup
Setup gives different settings and information of every inverter in the PV plant.
Figure 6.4.3: Setup
• Plant Information shows important characteristics of every inverter in the PV plant.
Model, serial number, revision and part no. information are all read-only.
• General Settings shows date and time, CO
2
- rating and rate and currency of the
earning. Settings can be modified.
• Alarm Setup shows information related to notifications and alarms from the
inverter/plant.
Notification Setup:
Type username and IP address/host name of the SMTP server, the
IP address of the inverter and mail address of the receiver(s).
Alarm Setup:
Type time for sending email messages (0 – 23 h) and the interval of
the messages (1440 min = 1 day).
Portal Setup:
The inverter may upload energy data to an FTP-server. Specify the
server address (either IP address or DNS) in the FTP Server IP field,
and optionally a username and password if needed. The data will
be uploaded every hour.
Note: only an inverter configured as a master will upload FTP data.
For third-party FTP services, an additional cost may be applied.
• Network shows the parameters related to the sending and receiving of email messages.
Type the IP address (configured with numbers like 192.168.10.20), network subnet mask
and gateway. Refer to 6.3.1.1. IP Address.
• User Account shows the current user accounts and provides the ability to setup and/or
change user names and passwords. The different levels are:
1. Guest:
Access level 1: Read only access to all values.
2. Owner:
Access level 2: Read and write access to all values and set levels except the
installer related values such as network settings and user accounts.
3. Admin:
Access level 3: Read and write access to all levels and set values.