Danfoss FP975 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Termostaty Danfoss FP975. Installation & User Instructions Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - 7-day electronic

FP975Installation & User Instructions7-day electronic programmer ®Certification Mark

Strany 2

10WiringNOTES:FOR SET2E LINKTERMINALS 1 & 5FP975 ON A SETWALLPLATEWiring Always switch off mains fi rst and never fi t programmer to a live wallplat

Strany 3 - Installation Instructions

11230 Vac Controlled Gravity Hot Water - Pumped Heating System PUMPED switch selection230 Vac Fully Pumped System - 3-port Mid-position Valve PUMPED s

Strany 4 - DIL Switch Settings

12Table ADANFOSS RANDALL FP975 (SET MODE)Fully Pumped Systems - ensure Pumped/Gravity switch is in ‘Pumped’ positionMAINS WATERN L ON COM OFFNL12 3DAN

Strany 5 - New Installation

13HEATINGNOTEThis conversion applies only if...An additional terminal block may be required where these disconnected leads (or pairs) should be termi

Strany 6

14Table A cont..DANFOSS RANDALL FP975 (SET MODE)MAINS WATERN L ON COM OFFNL1 2 3VENNER CHC/W2 (WITH STAT) N,2,4 L 1 - -VENNER CHC/W2 (AIR STAT LINKED)

Strany 7

15HEATINGNOTEThis conversion applies only if...An additional terminal block may be required where these disconnected leads (or pairs) should be termi

Strany 8

16Table BDANFOSS RANDALL FP975 (SET MODE)Gravity DHW, Pumped Heating Systems - ensure Pumped/Gravity switch is in ‘Gravity’ positionMAINSWATERN L ON C

Strany 9 - Existing Installation

17HEATINGNOTEThis conversion applies only if...An additional terminal block may be required where these disconnected leads (or pairs) should be termi

Strany 10 - N L 1 2 3 4 5 6

18Table B cont...DANFOSS RANDALL FP975 (SET MODE)MAINS WATERN L ON COMNL12VENNER VENOTROL N,A,M L,L1 V -VENNER VENOTROL 80 (AIR STAT)N,1,3,4L2 -VENNE

Strany 11

19HEATINGNOTEThis conversion applies only if...An additional terminal block may be required where these disconnected leads (or pairs) should be termi

Strany 12 - MAINS WATER

2IndexInstallation Product specifi cation 3 DIL switch settings 4-5 New Installation 5-8 Existing Installation 9 Wiring 10-11 Wiring Conversio

Strany 13

20What is a programmer?... an explanation for householders.Programmers allow you to set ‘On’ and ‘Off’ time periods. Some models switch the central he

Strany 14 - Table A cont

21User InstructionsYour programmerThe FP975 allows you to switch your heating and hot water on and off at times that suit you. You can programme up to

Strany 15

22Setting the correct Time and DayBefore you start This will reinstate the preset programmes and sets the time to 12.00pm on Monday (MO). Press and h

Strany 16

23SETTING THE DAY Press DAY repeatedly until the correct day of the week is displayed. MO is Monday, TU is Tuesday etc. Accepting the preset programm

Strany 17

24Before you change the preset programmesYour installer will have set your unit to operate in one of the following modes: 5/2 day - one set of progr

Strany 18 - Table B cont

25Programming the heating in 5/2 day mode1. Press PROG until SET CH ON TIME appears at the top of the display and MOTUWETHFR appears at the bottom o

Strany 19

264. Press the DAY button once and SASU will appear at the bottom of the display. Either press COPY to keep the same settings for Saturday and Sunday

Strany 20 - What is a programmer?

271. Press PROG until SET CH ON TIME appears at the top of the display and MO appears at the bottom of the display. Use the + and - buttons to set th

Strany 21 - User Instructions

28 Continue programming the rest of the week by pressing: a) NEXT ON/OFF button to move to the next setting, b) + and - buttons to amend the time

Strany 22 - Before you start

29Programming hot waterTo set the hot water programme press the PROG button until SET HW ON TIME appears on the display.Set the hot water programme in

Strany 23

3Please Note: This product should only be installed by a qualifi ed electrician or heating installer, and should be in accordance with the current edit

Strany 24 - Changing Preset Programmes

30 Running your Programme To run the central heating programme: press the SELECT button next to the radiator symbol. To run the hot water programm

Strany 25 - 5/2 day mode

31 The grey buttons next to the radiator symbol are the Heating override buttons. The grey buttons next to the tap symbol are the Hot Water override

Strany 26

32Open the fl ap on the front of the unit to reveal the programming buttons.To change from Summer to Winter (clocks back) -  press and hold - button.

Strany 30 - Running your Programme

36Danfoss Randall LtdAmpthill RoadBedfordMK42 9ERTel: 01234 364621Fax: 01234 219705Part No 8587 Issue 02 05/06Still having problems?Call your local

Strany 31 - Temporary override buttons

4DIL Switch SettingsDIL switch settingsBefore mounting the unit, ensure the 4 DIL switches on the rear of the unit have been moved to the required set

Strany 32

5Place the switch in the GRAVITY position if the system being controlled is a) fully pumped, but with only a single two port zone valve in the Heating

Strany 33

6Manufacturer Model Fully Pumped Systems Pumped/Gravity Selector Position Gravity H.W. Systems Pumped/Gravity Selector Position Wallplate Type Mode Sw

Strany 34

7New InstallationIMPORTANT NOTEIf the timeswitch to be replaced is listed below it may be worth considering a FP715 as an alternative to the FP975. Th

Strany 35

8New Installation6. A small blanking plug is supplied to blank the unused recessed bottom fi xing screw.7. Before setting the programmes the unit sho

Strany 36 - Department on 0845 121 7400

9Existing InstallationExisting InstallationEnsure that the power to the existing unit is switched off prior to removal.SYSTEMS RE-USING EXISTING WALLP