A complete system for flow •
calculation and pressure
measurement
Separate computing unit and main •
pressure unit
For manual and automatic •
balancing valve measurement
Computing unit enable editing and •
back-up of data on PC
Export results to Excel•
Print facility•
Comes as a complete kit with all •
accessories required
Multi-language•
Includes software •
Complete with moulded case•
PFM 4000 is a system for measuring flow
and performing hydronic balancing
in heating, cooling and domestic hot
water systems. PFM 4000 can also
be used for measuring pressure and
temperature.
The PFM 4000 system includes a main
pressure unit, which is connected
to the valve, and a computing unit.
The main pressure unit is measuring
flow, pressure and temperature and
transmitting the collected data to the
computing unit.
PFM 4000 comes in two versions:
PFM 4000 Standard, with wireless •
Bluetooth connection (up to 20m
transmission range)
PFM 4000 Multi-source, with wireless •
radio transmission (up to 30m
transmission range, expandable to
300m with routers)
PFM 4000 contains data for all Danfoss
balancing valves as well as for valves
from Cimberio, Comap, Esbe, Heimeier,
Herz, Honeywell, Oras, Oventrop,
Quitus, TA Hydronics and others.
PFM4000 Standard Suitcase Main Pressure Unit Code No.
HP iPAQ 214 computing unit including multi-language software (SD card),
AC adapter, sync/charge cable, HP software CD
Main pressure unit with Bluetooth transmission, including AC adapter
Polyamide measuring hoses (1.5 m), red and blue, with quick coupler for
Rectus nipples (2 pcs.)
3.0 mm measuring needles with Rectus nipple, for measuring hoses (2 pcs.)
Adapter hoses for old TA valves (2 pcs.)
TA adaptors with Rectus nipple, for measuring hoses, (2 pcs.)
Measuring adaptor for drain cock ¾” x Rectus nipple, for measuring hoses
(2 pcs.)
Measuring adaptor for drain cock ¾” x 3 mm measuring needles (2 pcs.)
Reduction nipples ¾” x ½” (2 pcs.)
Plastic bracket for mounting two measuring needle simultaneously
User Guide
10 bar 003L820000
20 bar 003L820100
PFM4000Standard PFM4000Multi-sourceSuitcase
HydronicMeasurementInstrument
PFM4000
PFM4000 Multi-source Suitcase Main Pressure Unit Code No.
SoMo 650 computing unit with radio card, including multi-language
software (SD card), AC adapter, sync/charge cable, Somo software CD
Main pressure unit with radio connection (2 pcs.), including 3,6 V power
supply (1 pc.)
Polyamide measuring hoses (1.5 m), red and blue, with quick coupler for
Rectus nipples (4 pcs.)
3.0 mm measuring needles with Rectus nipple, for measuring hoses (4 pcs.)
TA adaptors with Rectus nipple, for measuring hoses (2 pcs.)
Adapter hoses for old TA valves (2 pcs.)
Measuring adaptor for drain cock ¾” x Rectus nipple, for measuring hoses
(2 pcs.)
Measuring adaptor for drain cock ¾” x 3 mm measuring needles (2 pcs.)
Reduction nipple ¾” x ½” (2 pcs.)
Plastic bracket for mounting two measuring needle simultaneously
User Guide
10 bar 003L820200
20 bar 003L820300
Max. distances:
- between PFM and router . max. 30 m
- between 2 routers . max. 120 m
- between pressure unit and router . . max. 30 m