36 Installation Guide DLX series L00410622-01
Warning Box
Errors:
1. No communication
2. Wrong grid settings
Check the LEDs on the inverters. If the yellow and red are lit check that the installation is
correct performed and that the grid settings are correctly set.
If the ‘Start Installation’ screen is still shown, run through the installation process on the
inverter.
3.2. Self Test for Italy
The Self Test function is only valid for installation in Italy. It tests the inverters’ grid
monitoring function of voltage and frequency, and takes approximately 2 minutes.
NOTICE
The Self-Test can only be activated when:
The installation procedure is executed.
The country setting is set to Italy.
The inverter is in Running/Derating Mode.
Select: Commands>Inverter Commands>Self Test