Datasheet
Part No. 107v01 11/13
FP735Si -Electronic 3-channel Full Programmer
Speci cation
Features FP735Si
Order codes 087N789000
Factory set calendar clock
Automatic summer/winter time change
Fully independent Hot Water and Room Heating times
Room heating and hot water ON/OFF changes up to 6 per day per zone
Selectable 7 day, 5/2 day or 24 hour operating mode
+1, +2, +3 hour hot water and/or room heating override
Move to next event
Holiday mode
Optional service interval operation
Power supply 230Vac, 50 Hz
Switching action of output relay 2 x SPDT, 1 x SPST, type 1B
Switch rating of relay contact 3 x 3(1) A, 10-230 Volts
Rated impulse voltage 2.5 kV
Dimensions (mm) 140 wide x 91 high x 28 deep
Ball pressure test 75°C
Temperature range 5-30°C
Design standard EN 60730-2-7
Control pollution situation Degree 2
Memory backup Retained for the life of the product
Time accuracy +/- 1 minute per month
Wiring Details
Danfoss Ltd.
Ampthill Road
Bedford MK42 9ER
Tel: 01234 364621
Fax: 01234 219705
Website: www.heating.danfoss.co.uk
Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
VDHVA102
3 ON
2 ON
2 OFF
1 ON
1 OFF
CH Zone 1 OFF
L
N
CH Zone 1 ON
CH Zone 2 OFF
CH Zone 2 ON
HW Zone 3 ON